CVE-2016-8379

An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. Users are restricted to using short passwords.
References
Link Resource
http://www.securityfocus.com/bid/93550 Third Party Advisory VDB Entry
https://ics-cert.us-cert.gov/advisories/ICSA-16-287-05 Third Party Advisory US Government Resource
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:moxa:iologik_e1200_series_firmware:*:*:*:*:*:*:*:*
OR cpe:2.3:h:moxa:iologik_e1210:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1212:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1214:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1241:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1242:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1260:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1262:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:moxa:iologik_e1200_series_firmware:*:*:*:*:*:*:*:*
OR cpe:2.3:h:moxa:iologik_e1211:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1240:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:moxa:iologik_e1200_series_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e1213:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:moxa:iologik_e2200_series_firmware:*:*:*:*:*:*:*:*
OR cpe:2.3:h:moxa:iologik_e2214:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e2240:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e2242:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e2262:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:moxa:iologik_e2200_series_firmware:*:*:*:*:*:*:*:*
OR cpe:2.3:h:moxa:iologik_e2210:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e2260:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:moxa:iologik_e2200_series_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:moxa:iologik_e2212:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2017-02-13 21:59

Updated : 2024-02-28 15:44


NVD link : CVE-2016-8379

Mitre link : CVE-2016-8379

CVE.ORG link : CVE-2016-8379


JSON object : View

Products Affected

moxa

  • iologik_e1262
  • iologik_e2212
  • iologik_e1213
  • iologik_e2240
  • iologik_e1212
  • iologik_e1260
  • iologik_e1200_series_firmware
  • iologik_e1214
  • iologik_e1210
  • iologik_e1240
  • iologik_e2214
  • iologik_e1242
  • iologik_e1211
  • iologik_e2260
  • iologik_e2210
  • iologik_e2200_series_firmware
  • iologik_e1241
  • iologik_e2242
  • iologik_e2262