Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to an oversized value, an attacker could cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to this vulnerability can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599
References
Link | Resource |
---|---|
https://ics-cert.us-cert.gov/advisories/ICSA-13-095-02 | Third Party Advisory US Government Resource |
https://ics-cert.us-cert.gov/advisories/ICSA-13-095-02 | Third Party Advisory US Government Resource |
Configurations
Configuration 1 (hide)
|
History
21 Nov 2024, 01:52
Type | Values Removed | Values Added |
---|---|---|
References | () https://ics-cert.us-cert.gov/advisories/ICSA-13-095-02 - Third Party Advisory, US Government Resource |
Information
Published : 2019-03-26 18:29
Updated : 2024-11-21 01:52
NVD link : CVE-2013-2805
Mitre link : CVE-2013-2805
CVE.ORG link : CVE-2013-2805
JSON object : View
Products Affected
rockwellautomation
- rslinx_enterprise
CWE
CWE-125
Out-of-bounds Read