Multiple SQL injection vulnerabilities on the Sinapsi eSolar Light Photovoltaic System Monitor (aka Schneider Electric Ezylog photovoltaic SCADA management server), Sinapsi eSolar, and Sinapsi eSolar DUO with firmware before 2.0.2870_2.2.12 allow remote attackers to execute arbitrary SQL commands via (1) the inverterselect parameter in a primo action to dettagliinverter.php or (2) the lingua parameter to changelanguagesession.php.
References
Configurations
Configuration 1 (hide)
AND |
|
History
21 Nov 2024, 01:45
Type | Values Removed | Values Added |
---|---|---|
References | () http://archives.neohapsis.com/archives/bugtraq/2012-09/0045.html - Exploit | |
References | () http://www.exploit-db.com/exploits/21273/ - Exploit | |
References | () http://www.sinapsitech.it/default.asp?active_page_id=78&news_id=88 - | |
References | () http://www.us-cert.gov/control_systems/pdf/ICSA-12-325-01.pdf - US Government Resource | |
References | () https://exchange.xforce.ibmcloud.com/vulnerabilities/80201 - |
Information
Published : 2012-11-23 12:09
Updated : 2024-11-21 01:45
NVD link : CVE-2012-5861
Mitre link : CVE-2012-5861
CVE.ORG link : CVE-2012-5861
JSON object : View
Products Affected
sinapsitech
- sinapsi_firmware
- esolar_photovoltaic_system_monitor
- esolar_duo_photovoltaic_system_monitor
- esolar_light_photovoltaic_system_monitor
CWE
CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')